The diagnostic accuracy of left ventricular ejection fraction assessment between visual and artificial intelligence-based algorithms on bedside ultrasound

dc.contributor.authorKolobaric, Nikola
dc.contributor.authorBeauregard, Nickolas
dc.contributor.authorBarbour, William
dc.contributor.authorProsperi-Porta, Graeme
dc.contributor.authorParlow, Simon
dc.contributor.authorDi Santo, Pietro
dc.contributor.authorAbdel-Razek, Omar
dc.contributor.authorJung, Richard
dc.contributor.authorBradford, William B.
dc.contributor.authorTsang, Miranda
dc.contributor.authorPacifici, Stefano
dc.contributor.authorRamirez, F. D.
dc.contributor.authorHuggins, Gordon S.
dc.contributor.authorBugeja, Ann
dc.contributor.authorSimard, Trevor
dc.contributor.authorMathew, Rebecca
dc.contributor.authorHibbert, Benjamin
dc.contributor.authorMotazedian, Pouya
dc.contributor.authorMarbach, Jeffrey A.
dc.date.accessioned2026-09-01T04:34:24Z
dc.date.issued2026-08-31
dc.date.updated2026-09-01T04:34:24Z
dc.description.abstractAbstract Background Focused cardiac ultrasound (FoCUS) has become the standard of care for bedside assessments of cardiac function. With the integration of artificial intelligence (AI), there is limited evidence comparing it to bedside visual assessments by experienced users. Methods In our prospective study conducted at Tufts Medical Center in Boston, Massachusetts from December 2020 to March 2022, patients ≥ 18 years requiring a TTE were recruited by convenience sampling. They each underwent FoCUS LVEF classification by AI and bedside visual assessment, with TTE as reference. LVEF was calculated by Simpson’s biplane method of disks in AI-FoCUS and TTE, and visual global assessment by the bedside sonographer. Data analysis was completed in October 2025. Results Our 215 participants had a median age of 63 (IQR 49–73) years with 83 (38.6%) being female. AI-FoCUS assessments showed good agreement with TTE (intraclass correlation coefficient 0.84, 95% CI: 0.80–0.88), while visual assessments had stronger concordance (intraclass correlation coefficient 0.97, 95% CI: 0.96–0.98). Categorization of LV dysfunction severity showed excellent agreement with TTE for both AI-FoCUS (kappa 0.89, 95% CI: 0.84–0.94) and visual estimate (kappa 0.96, 95% CI: 0.92–0.99). For AI-FoCUS, the area under the curve (AUC) for identifying an abnormal LVEF (< 50%) was 0.9779 (95% CI: 0.9591–0.9967) with sensitivity 90.9% (95% CI: 88.1–100), specificity 95.6% (95% CI: 92.6–98.6), positive predictive value (PPV) 0.79 (95% CI: 0.66–0.92) and negative predictive value (NPV) 0.98 (95% CI: 0.96–1.00). For visual estimate, the AUC was 0.9961 (95% CI: 0.9915–1.000) with sensitivity 90.9% (95% CI: 88.1–100), specificity 97.8% (95% CI: 95.7–99.9), PPV 0.88 (95% CI: 0.77–0.99) and NPV 0.98 (95% CI: 0.96–1.00). Conclusion AI-assisted FoCUS LVEF assessments provide accurate estimates for the presence and severity of LV dysfunction but are outperformed in the latter by experienced bedside users. Graphical Abstract
dc.identifier.citationCardiovascular Ultrasound. 2026 Aug 31;24(1):20
dc.identifier.urihttps://doi.org/10.1186/s12947-026-00377-3
dc.identifier.urihttp://hdl.handle.net/10393/51996
dc.language.rfc3066en
dc.rights.holderThe Author(s)
dc.titleThe diagnostic accuracy of left ventricular ejection fraction assessment between visual and artificial intelligence-based algorithms on bedside ultrasound
dc.typeJournal Article

Fichiers

Trousse originale

Voici les éléments 1 - 1 sur 1
En cours de chargement...
Vignette d'image
Nom:
12947_2026_Article_377.pdf
Taille:
1.15 MB
Format:
Adobe Portable Document Format

Trousse de licence

Voici les éléments 1 - 1 sur 1
En cours de chargement...
Vignette d'image
Nom:
license.txt
Taille:
2.51 KB
Format:
Item-specific license agreed upon to submission
Description: